I/O device and external head amp
Reference Manual
145
Connecting the CL series console to an SB168-ES
To remotely control the SB168-ES from the CL series console, install an MY16-ES64 EtherSound card
in Slot 1 on the CL, then use an Ethernet cable to connect the CL to the SB168-ES. This connection
enables you to remotely control the SB168-ES from the CL series console.
Alternatively, you can use a daisy chain or ring connection and install two MY16-EX expansion cards
in the slots on the CL unit to remotely control up to three SB168-ES units simultaneously.
NOTE
Remote control data will be received and transmitted only at Slot 1 on the CL series console.
Daisy chain connection
Ring connection
NOTE
Please refer to the SB168-ES Owner’s Manual for information on setting up the MY16-ES64/
MY16-EX cards and EtherSound network.