Yamaha SRCX Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Nie Yamaha SRCX. Yamaha SRCX User`s manual [no] Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
Przeglądanie stron 0
Users Manual
ENGLISH
E
IM Operations
882 Soude, Naka-ku, Hamamatsu, Shizuoka 435-0054.Japan
URL http://www.yamaha-motor.jp/robot/index.html
YAMAHA MOTOR CO., LTD.
DeviceNet
YAMAHA NETWORK BOARD
SRCD/SRCP
ERCX/SRCX/DRCX
E73-Ver. 3.02
Przeglądanie stron 0
1 2 3 4 5 6 ... 81 82

Podsumowanie treści

Strona 1 - DeviceNet

User’s ManualENGLISHEIM Operations882 Soude, Naka-ku, Hamamatsu, Shizuoka 435-0054.JapanURL http://www.yamaha-motor.jp/robot/index.htmlYAMAHA MOTOR CO

Strona 2

4CHAPTER1 Cautions To Ensure Safety1-4 Start-up and maintenance safety points!CAUTIONNever attempt to disassemble the robot or controller. When a rob

Strona 3 - INTRODUCTION

5CHAPTER1 Cautions To Ensure Safety1-6 WarrantyFor information on the warranty period and terms, please contact our distributor whereyou purchased th

Strona 5 - Contents

CHAPTER22DeviceNet Unit

Strona 6

8CHAPTER2 DeviceNet Unit2-1 DeviceNet unit featuresDeviceNet is an FA field network developed by the Allen-Bradley Corporation in theUSA. Technical r

Strona 7 - Cautions To Ensure Safety

9CHAPTER2 DeviceNet Unit2-2 How the DeviceNet system worksThis brief description of how data is exchanged will help to understand how the control-ler

Strona 8 - 1-1 Basic safety points

10CHAPTER2 DeviceNet Unit2-3 DeviceNet cable connectionsWire the DeviceNet cable to the accessory DeviceNet plug. Make the wiring connec-tions by ref

Strona 9

11CHAPTER2 DeviceNet Unit2-4 Parallel I/O connectorThe I/O connector must be wired into the controller so install as shown below even if notusing the

Strona 10

12CHAPTER2 DeviceNet Unit When the SRCP/SRCD series is used:1. Short Pin No. 1 (EMG 1) and Pin No. 2 (EMG 2) of the EXT.CN connec-tor.2. Short Pin N

Strona 11 - 1-6 Warranty

13CHAPTER2 DeviceNet Unit2-5 Controller system settings (Slave station)The MAC ID and the communication speed must be set so that the controller can

Strona 13 - DeviceNet Unit

14CHAPTER2 DeviceNet Unit2-5-2 Setting MAC ID and communication speed!CAUTIONAlways be sure to turn off power to the controller before attempting to

Strona 14 - 2-1 DeviceNet unit features

15CHAPTER2 DeviceNet Unit2-5-3 How to check MAC ID and communication speedMAC ID and communication speed settings made with a DIP switch on the board

Strona 15 - CHAPTER2 DeviceNet Unit

16CHAPTER2 DeviceNet Unit2-6 Sequencer (master station) settingsThe master station sequencer (or PLC) in the DeviceNet system can make line tests ont

Strona 16 - Controller

17CHAPTER2 DeviceNet Unit2-7 I/O informationOn/off (I/O) information handled by the DeviceNet unit consists of 16 custom inputs, 16general-purpose I/

Strona 17 - 2-4 Parallel I/O connector

18CHAPTER2 DeviceNet Unit!CAUTION•The above profile is for cases where the I/O assignment selection parameter isset to "Type 0: Conventional typ

Strona 18

19CHAPTER2 DeviceNet Unit Point movement command with absolute (ABS-PT)When origin point coordinates are set at 0, this command moves the robot to a

Strona 19

20CHAPTER2 DeviceNet Unit Origin return command (ORG-S)This command performs origin return when the search method was selected as theorigin detectio

Strona 20 - 1 2 3 4 5 6 7 8

21CHAPTER2 DeviceNet Unit Reset command (RESET)This command returns the program step to the first step of the lead program, andturns DO0 - DO12*1, S

Strona 21

22CHAPTER2 DeviceNet Unit2-7-3 General-purpose inputs (SI200 - SI215)General-purpose inputs are inputs freely available to the user for handling as d

Strona 22

23CHAPTER2 DeviceNet Unit2-7-4 Interlock (LOCK)These are inputs to temporarily stop robot movement.Robot operation can be stopped by setting this inp

Strona 23 - 2-7 I/O information

INTRODUCTIONThank you for purchasing the DeviceNet unit for the YAMAHA single-axis/dual-axisrobot controllers SRCP/SRCD/ERCX/SRCX/DRCX series.This is

Strona 24

24CHAPTER2 DeviceNet Unit2-7-6 Service mode (SVCE)This input is enabled only when the controller unit has itself been set to service mode.The SVCE (s

Strona 25

25CHAPTER2 DeviceNet Unit2-7-7 Custom outputsCustom outputs inform the sequencer (PLC) of controller status. "Preparation completed" outp

Strona 26

26CHAPTER2 DeviceNet Unit "Servo status" output (SRV-O)Displays the robot servo status.This turns ON when all axes are at servo-ON. Howeve

Strona 27

27CHAPTER2 DeviceNet Unit2-8 Timing chartTypical timing charts are shown below, so refer to them when creating the PLC program.2-8-1 Right after cont

Strona 28 - Specifying a point number

28CHAPTER2 DeviceNet Unit2-8-2 Custom input command execution The BUSY output turns ON when a dedicated command input is received. Whetheror not th

Strona 29 - 2-7-4 Interlock (LOCK)

29CHAPTER2 DeviceNet Unit(2) When a short execution time command runs and ends normally(In the following cases, when the dedicated command input is t

Strona 30 - 2-7-6 Service mode (SVCE)

30CHAPTER2 DeviceNet UnitDedicatedcommandBUSYEND30ms or less 1ms or less 1ms or less1ms or lessDedicated commandexecution completionEven after dedica

Strona 31 - 2-7-7 Custom outputs

31CHAPTER2 DeviceNet Unit(4) When an on-going command becomes impossible to run(In the following cases, END will not turn ON, when running of an on-g

Strona 32

32CHAPTER2 DeviceNet Unit2-8-3 When interlock signal is inputDedicatedcommandBUSYENDLOCKDiffers according to execution commandInterlock The BUSY out

Strona 33 - 2-8 Timing chart

33CHAPTER2 DeviceNet Unit2-8-4 When emergency stop signal is inputDedicatedcommandBUSYENDEMGREADY5ms or less 1ms or lessEmergency stop The READY out

Strona 35

34CHAPTER2 DeviceNet Unit2-8-5 When an alarm is issuedDedicatedcommandBUSYENDREADY5ms or less 1ms or lessAlarm The READY, BUSY and END outputs all t

Strona 36

35CHAPTER2 DeviceNet Unit2-8-6 When point movement commands are run When executing a point movement command (ABS-PT, INC-PT), the point dataand spee

Strona 37 - Command execution impossible

36CHAPTER2 DeviceNet Unit2-9 I/O assignment change function2-9-1 Changing the I/O assignmentThe I/O assignment change function changes the function a

Strona 38 - Interlock

37CHAPTER2 DeviceNet Unit2-9-2 I/O assignment listThe table below shows the function assigned to each input/output (I/O) signal by settingthe I/O ass

Strona 39

38CHAPTER2 DeviceNet UnitnOutput (Remote → Master)n+1bit0bit1bit2bit3bit4bit5bit6bit7bit8bit9bit10bit11bit12bit13bit14bit15bit0bit1bit2bit3bit4bit5bi

Strona 40 - 2-8-5 When an alarm is issued

39CHAPTER2 DeviceNet Unit2-9-3 I/O assignment selection parameter descriptionThe I/O assignment selection parameter (single-axis controllers: PRM59,

Strona 41

40CHAPTER2 DeviceNet Unite Point zone judgment method selectionThe position judgment parameter is selected when the pointoutput selection is "2&

Strona 42

41CHAPTER2 DeviceNet Unit2-9-4 I/O signal descripionThe meaning of each signal is explained below. For the meaning of signals not describedhere, refe

Strona 43 - 2-9-2 I/O assignment list

42CHAPTER2 DeviceNet UnitAxis selection exampleSI214 SI213OFFONOFFONJOG+, JOG-Selected axisX-axisX-axisY-axisX-axisOFFOFFONON!CAUTION• If the CHG (mo

Strona 44

43CHAPTER2 DeviceNet Unit Point data write command (PSET)Writes the current position data in the specified point number.To use this command, the poi

Strona 45

ContentsContentsCautions To Ensure Safety ...11-1 Basic safety points ...

Strona 46

44CHAPTER2 DeviceNet UnitTarget position point numbers for point movement commands (ABS-PT, INC-PT)are output as binary values. The same applies to p

Strona 47 - 2-9-4 I/O signal descripion

45CHAPTER2 DeviceNet UnitMEMOMEMOWhen using PO as an output signal that indicates the target position's point numberfor point movement commands

Strona 48

46CHAPTER2 DeviceNet Unit2-9-5 Timing chartThis section shows timing charts for the operations that are added by changing the I/Oassignment. Jog mov

Strona 49

47CHAPTER2 DeviceNet Unit Point data write (PSET)CHG(Mode switch input)PSET(Point data write command)(Point number designation inputs

Strona 50

48CHAPTER2 DeviceNet Unit Target position's point number output (PO)(1) Outputting the point number at the timing that movement is normallycomp

Strona 51

49CHAPTER2 DeviceNet Unit[Point movement command execution w](8) Execute the next point movement command.(9) Point movement ends.(10) The END signal

Strona 52 - 2-9-5 Timing chart

50CHAPTER2 DeviceNet Unit(2) Outputting the point number at the timing that a movement command isreceivedABS-PT/INC-PTĦPoint movement commandħĦTarget

Strona 53

51CHAPTER2 DeviceNet Unit[Point movement command execution w](8) Execute the next point movement command.(9) When the controller received the point m

Strona 54

52CHAPTER2 DeviceNet Unit(3) Outputting the corresponding point number by the point zone outputfunctionZone outputs (ZONE 0, ZONE 1) are also explain

Strona 55

53CHAPTER2 DeviceNet Unit(2) Outputs the corresponding point number through PO200 to PO203 since thecurrent robot position is within the point zone o

Strona 56

2-13 Error message... 642-14 Troubleshooting...

Strona 57

54CHAPTER2 DeviceNet Unit(4) Outputting the corresponding point number by the movement point zoneoutput functionZone outputs (ZONE 0) are also explai

Strona 58

55CHAPTER2 DeviceNet Unit(3) The corresponding point number P6 is output to PO200 through PO203 (P201,P202 are on; P200, P203 are off) because the ro

Strona 59 - (binary)). This

56CHAPTER2 DeviceNet Unit2-10 Robot languageThe robot language expanded by using in the DeviceNet unit.2-10-1 MOVFFunction: Moves until the specified

Strona 60

57CHAPTER2 DeviceNet Unit2-10-2 JMPFFunction: Jumps to the specified label of the specified program when the jump con-dition input matches the value

Strona 61

58CHAPTER2 DeviceNet Unit2-10-3 JMPBFunction: Jumps to the specified label when the specified general-purpose input ormemory input or serial general-

Strona 62 - 2-10 Robot language

59CHAPTER2 DeviceNet Unit2-10-5 WAITFunction: Waits until the specified general-purpose input or memory input or serialgeneral-purpose input sets to

Strona 63 - 2-10-2 JMPF

60CHAPTER2 DeviceNet Unit2-11 Emulated Serialization on parallel DIOThis is a function to directly send the input from the master sequencer (PLC) to

Strona 64 - 2-10-4 DO

61CHAPTER2 DeviceNet Unit1) Press F3 (SYS) on the initial screen.2) Press F4 (next) to switch to the func-tion display. When the function displayappe

Strona 65 - 2-10-5 WAIT

62CHAPTER2 DeviceNet Unit2-12 Other operations2-12-1 Serial I/O displaySerial I/O (input/output) status can be displayed on the screen.1) Press F2 (O

Strona 66 - Emulated serialization

63CHAPTER2 DeviceNet Unit2-12-2 Manual control of general-purpose outputThe serial general-purpose output can be manually controlled from HPB.1) Pres

Strona 67

CHAPTER11Cautions To Ensure Safety

Strona 68 - 2-12 Other operations

64CHAPTER2 DeviceNet Unit2-13 Error messageThe following error message was added to the DeviceNet system.Error No.38Message (English)CauseRemedynet l

Strona 69

65CHAPTER2 DeviceNet Unit2-14 TroubleshootingCheck the following items if any problems occur during operation. Also, refer to "Trou-bleshooting&

Strona 70 - 2-13 Error message

66CHAPTER2 DeviceNet UnitCheckpoints• Check if an error has occurred by monitoring the network status information on master PLC.• Referring to "

Strona 71 - 2-14 Troubleshooting

67CHAPTER2 DeviceNet Unit2-15 Specifications2-15-1 Unit basic specificationsDeviceNet UnitSRCP/SRCD/ERCX/SRCX/DRCX series controllerConforms to Devic

Strona 72

68CHAPTER2 DeviceNet Unit General Device DataConforms to DeviceNet SpecificationVendor NameDevice Profile Name Product CodeProduct RevisionVolume

Strona 73 - 2-15 Specifications

69CHAPTER2 DeviceNet Unit DeviceNet Required Object Implementation● Identity Object(0x01)Object ClassAttributesServicesNone SupportedNone SupportedO

Strona 74 - ■ General Device Data

70CHAPTER2 DeviceNet UnitObject ClassGet Set Value LimitDeviceNet Services Parameter OptionsAttributesServicesID10EHDescriptionRevisionGet_Attribute_

Strona 75

71CHAPTER2 DeviceNet Unit● Connection Object(0x05)Object ClassAttributesServicesTotal ActiveConnectionsPossibleNone SupportedNone Supported1Object In

Strona 76 - Object Instance

72CHAPTER2 DeviceNet UnitObject Instance 2Get SetParameter OptionsSectionAttributesServices ID12345678912131415161705H0EH10HDescriptionState Instance

Strona 77 - Object Instance 1

73CHAPTER2 DeviceNet UnitObject Instance 3Get SetParameter OptionsSectionAttributesServices ID12345678912131415161705H0EH10HDescriptionState Instance

Strona 78

2CHAPTER1 Cautions To Ensure Safety1-1 Basic safety pointsBesides reading this instruction manual and the controller user's manual, also be sure

Strona 79

74CHAPTER2 DeviceNet Unit$ DeviceNet Configurator Generated Electronic Data Sheet[File] DescText = "YAMAHA ROBOT EDS File"; $ File Des

Strona 81

User's ManualAll rights reserved. No part of this publication may be reproduced in any form without the permission of YAMAHA MOTOR CO., LTD.Infor

Strona 82

3CHAPTER1 Cautions To Ensure Safety1-3 Installation and wiring safety points!CAUTIONAlways cut off all power to the controller and the overall system

Komentarze do niniejszej Instrukcji

Brak uwag